Certification: | RoHS, ISO9001, CE, ERP |
---|---|
Working Medium: | R32 |
Heat Source Type: | Air Source Heat Pump |
Color: | Black |
Warranty: | 2 Years |
APP-Control: | Yes |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Model | MLS-AM-60 | MLS-AM-90 | MLS-AM-120 | MLS-AM-160 | |
Heating at A20/W35ºC | |||||
Heating output | KW | 8.44 | 12.1 | 16.32 | 21.88 |
Power input | KW | 1.41 | 2.02 | 2.77 | 3.66 |
COP | 5.99 | 5.99 | 5.89 | 5.98 | |
Heating at A7/W35ºC | |||||
Heating output | KW | 6.21 | 8.9 | 12 | 16.3 |
Power input | KW | 1.26 | 1.81 | 2.5 | 3.34 |
COP | 4.93 | 4.92 | 4.8 | 4.88 | |
Heating at A2/W35ºC | |||||
Heating output | KW | 5.56 | 7.97 | 10.8 | 14.49 |
Power input | KW | 1.22 | 1.76 | 2.44 | 3.23 |
COP | 4.56 | 4.53 | 4.43 | 4.49 | |
Cooling at A35/W7ºC | |||||
Cooling output | KW | 4.9 | 5.9 | 8.1 | 11.4 |
Power input | KW | 1.65 | 2 | 2.83 | 4 |
COP | 2.97 | 2.95 | 2.86 | 2.85 | |
Compressor | DC Inverter Twin Rotary | ||||
Max Current | A | 13 | 13 | 19 | 25 |
Electric supply | 230V/50Hz | 230V/50Hz | 230V/50Hz | 230V/1Ph Hz | |
Max LWT | ºC | 60 | |||
Operating temperature range | ºC | -25~43 | |||
Refrigerant | R32 | ||||
Heat Exchanger | Copper and Hydrophilic Aluminum Fin | ||||
Air flow | M³/h | 2100 | 2400 | 2900 | 5600 |
Heat exchanger | Plate heat exchanger | ||||
In/Out pipe | DN25(1") | DN25(1") | DN25(1") | DN32 | |
Water flow | M³/h | ≥0.8 | ≥1.2 | ≥1.8 | ≥2.3 |
Permitted pressure | ≤0.8MPa | ||||
Unit dimensions LXWXH | mm | 1115x425X710 | 1115x425x710 | 1115x425x960 | 1115x425x1280 |
Package dimension LXWXH | mm | 1160x520x860 | 1160x520x860 | 1160x520x1110 | 1160x520x1440 |
Net Weight | Kg | 90 | 90 | 105 | 140 |
Gross weight | Kg | 102 | 102 | 115 | 140 |
Noise level | dB(A) | 46 | 46 | 50 | 52 |
Loading quantity for 20'/40' | 44/88 | 44/88 | 44/88 | 22/44 |
Full DC Inverter Technology
With this technology, user can enjoy a maximum level of comfort at the lowest costs monobloc heat pump in the market is to save space and money. For sure, the R32 Full inverter heat pump will be the future trend.
Quiet Operation
Thanks to engineers' elaborate design and constant effort toreduce the noise,
Residential air to water heat pump can run amazingly quietly of 45dB(A) in sleep mode.
Maximum Water temperature 60°C
The highest water temperature can reach 60 degrees, can uninterruptedly meet the bathing needs of the whole family, so that you can experience a sound surging bath.
EVI Monobloc Air to Water Heat Pumps Working Principle Diagram
Vegardis provides the monoblock heat pump with an integrated main circulation pump. During installation, the installer needs to ensure the proper connection of the heat pump with other components, such as the buffer tank (for space heating/cooling), storage water tank (for domestic hot water), and water pumps (for circulating space heating/cooling water and domestic hot water)Additionally, external fittings are required, including the safety valve, water refill valve, and hot water valves (three-way valve). lt is necessary to incorporate a temperature sensor in the storage water
Suppliers with verified business licenses