• Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential
  • Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential
  • Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential
  • Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential
  • Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential
  • Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential

Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential

Certification: ISO9001, CE, ISO14001
Working Medium: R32
Heat Source Type: Air Source Heat Pump
Color: Black
Warranty: 2 Years
APP-Control: Yes
Samples:
US$ 1900/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
MLS-AM-120
OEM
Yes
Installation
Freestanding
Lead Time
15-30 Days
Water Pump
Wilo
Max Outlet Water Tem.(R32)
60ºC
Compressor
Mitsubishi* Inverter Twin Rotary Compressor
Type
Monoblock
Refrigerant
R32
Indoor Heat Exchanger
Plate Heat Exchanger
Net Weight
105kg
Transport Package
Plastic Bag Inside with Wooden Frame
Specification
1115mm*960mm*425mm
Trademark
Vegardis or OEM
Origin
China
HS Code
8418612090
Production Capacity
30000 Pieces/Year

Product Description

Factory direct sale  monoblock low ambient air to water heat pump for residential 
Famous brand main component for air source heat pump 
R32 DC INVERTER ROTARY COMPRESSOR

Mitsubishi R32 DC Inverter Compressor provides the utmost satisfaction by possession of product leadership in the compressor business world with variable range of Rotary compressor for heat pump

High efficiency Mitsubishi Inverter compressor show the superior technology of reduced noise and vibration in extensive durability and reliability
* Full Line-up with various efficiency
* Wide range of discharge capacity
* World Highest Efficiency in non-Variable speed Rotary
* Work under wide voltage range
* High Torque Motor & High Performance Mechanism
* Compact design     

Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential
 Saginomiya 4 way valves
•Pilot operated 4-way reversing valves are suitable for heat pump applications on unitary, split system and window type air conditioners, etc.
•4-way pilot valve adoption has an advantage on reliable changeover operations.
•Designed to lower the minimum operating pressure difference between high and low side. Pressure drop and valve leakage are minimized.
Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for ResidentialWilo dc inverter water pump for air source heat pump
High integration flexibility due to compatibility with former standard and high-efficiency series and a wide range of specific pump housings
Easy installation thanks to a compact and standardised design with front access to signal connector and screws
Exists in 3 different control modes to respond better to your specific needs:
Self-controlled (SC) version allowing several regulation modes and settings, easy to handle thanks to the green push button combined with a LED interface
External control mode through iPWM signal for direct information on pump status and flow estimation directly from the pump itself
External LIN control mode allowing many data exchanges between the pump and the appliance to go a step further on digitalisation. Extended functionalities through the LIN extended mode LINX
High system protection due to integrated functionalities such as air venting, manual restart as well as reset to factory settings upon control mode
Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential
Model   MLS-AM-60 MLS-AM-90 MLS-AM-120 MLS-AM-160
Heating capacity A7/W35ºC(EN14511) KW 6.21KW 8.9KW 12KW 16.3
Heating capacity A2/W35ºC(EN14511) KW 5.56 7.97 10.8 14.49
COP A2/W35(EN14511)     4.56 4.53 4.43 4.49
COP A7/W35 (EN14511)   4.93 4.92 4.8 4.88
Cooling capacity A35/W7ºC KW 4.9 5.9 8.1 11.4
EER A35/W7 (EN14511)   2.97 2.95 2.86 2.85
Cooling capacity A35/18 (EN14511) KW 6.35 8.1 11 15.6
EER A35/W18 (EN14511)   3.97 3.89 3.53 3.63
Electric supply   230V/50Hz 230V/50Hz 230V/50Hz 230V/1Ph Hz
Refrigerant   R32
Unit dimensions LXWXH mm 1115x425X710 1115x425x710 1115x425x960 1115x425x1280
Package dimension LXWXH mm 1160x520x860 1160x520x860 1160x520x1110 1160x520x1440
Net Weight Kg 90 90 105 140
Noise level dB(A) 46 46 50 52
Loading quantity for 20'/40'   44/88 44/88 44/88 22/44

Product Description

Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for ResidentialFactory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential
Full DC Inverter Technology
With this technology, user can enjoy a maximum level of comfort at the lowest costs monobloc heat pump in the market is to save space and money. For sure, the R32 Full inverter heat pump will be the future trend.
Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for ResidentialQuiet Operation
Thanks to engineers' elaborate design and constant effort toreduce the noise,
Residential air to water heat pump can run amazingly quietly of 45dB(A) in sleep mode.


Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential
Maximum Water temperature 60°C
The highest water temperature can reach 60 degrees, can uninterruptedly meet the bathing needs of the whole family, so that you can experience a sound surging bath.

Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for ResidentialFactory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for ResidentialFactory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for ResidentialFactory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for ResidentialFactory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential
EVI Monobloc Air to Water Heat Pumps Working Principle Diagram
Vegardis provides the monoblock heat pump with an integrated main circulation pump. During installation, the installer needs to ensure the proper connection of the heat pump with other components, such as the buffer tank (for space heating/cooling), storage water tank (for domestic hot water), and water pumps (for circulating space heating/cooling water and domestic hot water)Additionally, external fittings are required, including the safety valve, water refill valve, and hot water valves (three-way valve). lt is necessary to incorporate a temperature sensor in the storage water

Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for ResidentialFactory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential

Company Profile

Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for ResidentialFactory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for ResidentialFactory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential

 

FAQ

Factory Direct Sale Monoblock Low Ambient Air to Water Heat Pump for Residential

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
50000000 RMB
Plant Area
30000 square meters