16kw China Monoblock Air to Water Heat Pump for Radiant Floor Heating Space heating cooling and Hot Water
ECO friendly new refrigerant: R32
GWP (Global Warming Potential) only 675, only approximately 1/3 compare with R410A.
15 years in manufacturing heat pump
Well-known brand compressor, twin-rotary and DC Inverter technology, the twin rotors balance each other for anti-vibration,creates lower noise but more efficient.
Welling Brushless DC fan motor, with good quality of long time running test and low noise.
Saginomiya brand electronic expansion valve for precise refrigerant control.
Vilo Water pump,Low noise, low vibration, high efficiency, high reliability, easy maintenance
High COP/EER performance for save energy
Model |
|
VLKS-06CPB2B |
VLKS-09CPB2B |
VLKS-12CPB2B |
VLKS-16CPB2B |
Heating capacity A7/W35ºC(EN14511) |
KW |
6.21KW |
8.9KW |
12KW |
16.3 |
Heating capacity A2/W35ºC(EN14511) |
KW |
5.56 |
7.97 |
10.8 |
14.49 |
COP A2/W35(EN14511) |
|
4.56 |
4.53 |
4.43 |
4.49 |
COP A7/W35 (EN14511) |
|
4.93 |
4.92 |
4.8 |
4.88 |
Cooling capacity A35/W7ºC |
KW |
4.9 |
5.9 |
8.1 |
11.4 |
EER A35/W7 (EN14511) |
|
2.97 |
2.95 |
2.86 |
2.85 |
Cooling capacity A35/18 (EN14511) |
KW |
6.35 |
8.1 |
11 |
15.6 |
EER A35/W18 (EN14511) |
|
3.97 |
3.89 |
3.53 |
3.63 |
Electric supply |
|
230V/50Hz |
230V/50Hz |
230V/50Hz |
230V/1Ph Hz |
Refrigerant |
|
R32 |
Unit dimensions LXWXH |
mm |
1115x425X710 |
1115x425x710 |
1115x425x960 |
1115x425x1280 |
Package dimension LXWXH |
mm |
1160x520x860 |
1160x520x860 |
1160x520x1110 |
1160x520x1440 |
Net Weight |
Kg |
90 |
90 |
105 |
140 |
Noise level |
dB(A) |
46 |
46 |
50 |
52 |
Loading quantity for 20'/40' |
|
44/88 |
44/88 |
44/88 |
22/44 |
Customer review of heat pump
Monobloc Air Source Heat Pumps Working Principle Diagram.
Vegardis provides the monobloc heat pump with an integrated main circulation pump. During installation, the installer needs to ensure the proper connection of the heat pump with other components, such as the buffer tank (for space heating/cooling), storage water tank (for domestic hot water), and water pumps (for circulating space heating/cooling water and domestic hot water)Additionally, external fittings are required, including the safety valve, water refill valve, and hot water valves (three-way valve). lt is necessary to incorporate a temperature sensor in the storage water tank. Furthermore, an additional electric heater can be installed in either the DHW tank or the buffer tank, allowing it to receive control signals from the heat pump.
Vegardis heat pump project display