Vegardis R290 A+++ ERP CE DC inverter heat pump large factory OEM ODM service 9kw 12kw 15kw
1.A+++ energy efficiency grade |
2.R290 refrigerant, green environmental protection (GWP=3, ODP=0) |
3.Heating, cooling, hot water, super triple-supply, one-stop solutions |
4.Full DC full frequency conversion technology (compressor, fan, pump) |
5.Stable operation at ambient temperatures from -25ºC to 45ºC |
6.Water discharge up to 75 ° C |
7.High energy efficiency, low noise, noise as low as 40dB |
8.Intelligent IOT, support Wifi access, support OTA, easy online maintenance and upgrading |
9.Intelligent APP, remote control, one step ahead of comfort |
10.Intelligent touch controller, support up to 8 languages |
11.Support RS485 interface, support whole-house intelligent connection |
12.Support smart grid technology and smart meter connection |
Model |
/ |
VLKS-09CPC2B |
VLKS-09CPC3B |
VLKS-12CPC2B |
VLKS-12CPC3B |
VLKS-15CPC2B |
VLKS-15CPC3B |
VLKS-22CPC2B |
VLKS-22CPCB |
Power Supply |
/ |
220V-240V~/50Hz |
380V-415V~/3N/50Hz |
220V-240V~/50Hz |
380V-415V~/3N/50Hz |
220V-240V~/50Hz |
380V-415V~/3N/50Hz |
220V-240V~/50Hz |
380V-415V~/3N/50Hz |
Heating Condition-Ambient Temp.(DB/WB): 7/6ºC, Water Temp.(In/Out): 30/35ºC |
Heating Capacity Range |
kW |
2.90~9.05 |
2.90~9.05 |
4.20~12.00 |
4.20~12.00 |
4.5~15.10 |
4.5~15.10 |
8.0~21.50 |
8.0~21.50 |
Heating Power Input Range |
kW |
0.62~1.80 |
0.62~1.80 |
0.80~2.90 |
0.80~2.90 |
0.90~3.63 |
0.90~3.63 |
1.50~5.40 |
1.50~5.40 |
COP |
kW/kW |
4.25~5.20 |
4.25~5.20 |
4.23~5.22 |
4.23~5.22 |
4.15~5.25 |
4.15~5.25 |
4.00~5.21 |
4.00~5.21 |
Heating Condition-Ambient Temp.(DB/WB): 7/6ºC, Water Temp.(In/Out): 47/55ºC |
Heating Capacity Range |
kW |
3.00~8.10 |
3.00~8.10 |
4.05~11.00 |
4.05~11.00 |
4.35~14.2 |
4.35~14.2 |
7.6~19.00 |
7.6~19.00 |
Heating Power Input Range |
kW |
1.05~2.95 |
1.05~2.95 |
1.38~3.05 |
1.38~3.05 |
1.30~4.82 |
1.30~4.82 |
2.30~6.80 |
2.30~6.80 |
COP |
kW/kW |
2.80~3.35 |
2.80~3.35 |
2.90~3.37 |
2.90~3.37 |
2.95~3.36 |
2.95~3.36 |
2.85~3.35 |
2.85~3.35 |
Cooling Condition-Ambient Temp.(DB/WB): 35/24ºC, Water Temp.(In/Out): 12/7ºC |
Cooling Capacity Range |
kW |
1.50~6.0 |
1.50~6.0 |
3.0~8.0 |
3.0~8.0 |
5.5~10.5 |
5.5~10.5 |
7.0~17.0 |
7.0~17.0 |
Cooling Power Input Range |
kW |
0.60~2.26 |
0.60~2.26 |
0.94~3.02 |
0.94~3.02 |
1.72~3.35 |
1.72~3.35 |
2.15~6.30 |
2.15~6.30 |
EER |
kW/kW |
2.65~3.05 |
2.65~3.05 |
2.66~3.21 |
2.66~3.21 |
2.70~3.15 |
2.70~3.15 |
2.71~3.20 |
2.71~3.20 |
Max. Power Input |
kW |
3.7 |
3.7 |
4.5 |
4.5 |
5.5 |
5.5 |
7.5 |
7.5 |
Max. Current lnput |
A |
16.1 |
5.6 |
19.6 |
6.9 |
23.9 |
8.4 |
32.6 |
11.4 |
ErP Level (35ºC) |
/ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
ErP Level (55ºC) |
/ |
A++ |
A++ |
A++ |
A++ |
A++ |
A++ |
A++ |
A++ |
Water Flow |
m³/h |
1.55 |
1.55 |
2.06 |
2.06 |
2.6 |
2.6 |
3.7 |
3.7 |
Refrigerant |
/ |
R290 |
R290 |
R290 |
R290 |
R290 |
R290 |
R290 |
R290 |
Proper Input |
kg |
0.50 |
0.50 |
0.70 |
0.70 |
1.00 |
1.00 |
1.20 |
1.20 |
CO2,Equivalent |
Ton |
0.0015 |
0.0015 |
0.0021 |
0.0021 |
0.0030 |
0.0030 |
0.0036 |
0.0036 |
Sound Pressure at 1m Distance |
dB(A) |
48 |
48 |
50 |
50 |
53 |
53 |
56 |
56 |
Operating Ambient Temperature |
ºC |
Heating Mode : -25~45 / Cooling Mode : 15~45 |
Max. Water Temperature |
ºC |
75 |
Compressor Brand |
/ |
GMCC |
Water Side Heat Exchanger |
/ |
Plate type |
Water Side Heat Exchanger Brand |
/ |
WEYEE |
Cabinet Type |
/ |
Galvanized sheet |
Fan Motor Type |
/ |
Brushless DC motor |
Fan Quantity |
/ |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
Water Connection |
/ |
G1.2" |
G1.2" |
G1.2" |
G1.2" |
G1.2" |
G1.2" |
G1.2" |
G1.2" |
Circulation Pump |
brand |
SHIMGE |
Circulation Pump Water Head |
m |
9 |
9 |
9 |
9 |
9 |
9 |
12 |
12 |
Unit Dimension(L/W/H) |
mm |
1230×480×825 |
1230×480×825 |
1230×480×825 |
1230×480×825 |
1280×480×928 |
1280×480×928 |
1180×480×1475 |
1180×480×1475 |
Shipping Dimensions(L/W/H) |
mm |
1389×612×1014 |
1389×612×1014 |
1389×612×1014 |
1389×612×1014 |
1439×612×1115 |
1439×612×1115 |
1339×612×1664 |
1339×612×1664 |
Net/Gross weight |
kg |
105/120 |
110/125 |
120/135 |
125/140 |
130/150 |
135/155 |
185/205 |
190/210 |


What is Global Warming Potential(GWP) of heat pumps
GWP is a comparative value that indicates the green house effect of a greenhouse gas,such as
a refrigerant.If it were to be released into the enviroment.The higher the value,the worse impact on the climate.
Exemplary GWPs of some refrigerants:
The value indicates the amount of CO2 which has an equal global warming effect.To Calculate the CO2 impact of a refrigerant,the amount contained in the heat pump is multiplied by its GWP value
CO2 |
1 |
R290 |
3 |
R32 |
675 |
R410A |
2088 |
R290 air source heat pump highlights feature



Molisi Technology was founded in 2004, focusing on heat pump R&D, manufacturing air to water heat pump from 6kw to 18kw.
Molisi Technology offers the best solution for heating cooling and hot water supply with dc inverter technology. Vegardis heat pump has always been committed to saving energy. DC inverter EVI technology can effectively reduce power consumption and improve the heating performance of heat pump units to ensure stable performance even at ambient temperatures as low as -35°C.
Molisi Factory has obtained ISO9001, ISO14001,ISO45001 certificates
Main products:
R290 refrigerant air to water heat pump
R32 refrigerant air source heat pump
Advantage:
15 years exporting experience
Strong R&D team
Custom made service
CE certificate,ERP A+++
As an international enterprise targeting the global market, Molisi attaches great importance to high-end global market, Till now our products have exported to over 30 countries and region.





1.How many years have your company been in heat pump industry?
Over 15 years in heat pump industry with 200 staff,20 engineers team
2.Do you have laboratory?
45KW Air Source Heat Pump Unit Performance Laboratory
applicable refrigerant: R290, R32,410A, R134A, R22, R404A, R407A,
laboratory air-side dry bulb temperature control range: -35 ~ +50 ºC;
3. Do you accept OEM & ODM?
Yes. We can produce high quality custom made air source heat pump according to customers' requirement, modify the products to satisfy client's requirements and work together with clients to design a new product.
4. What support do you offer to clients?
We can provide product certification requirements for local markets; provide catalogs, technical manuals;
5.How long is the Heat Pump delivery time?
Generally production time will be 25-40 days,
6.What is your terms of payment for heat pump ?
For small order,100% paid in advance. For big order 30% T/T in advance ,balance before shipment.
7.How long can I get feedback after sending inquiry
We will check inquiry and message everyday.Our sales clerk will reply to you accordingly in 24 hours. Please complete your email and telephone or mobile number in your personal information so that we can contact you soon.
8.How about the quality control?
Finished products 100% inspected before package,ISO9001 factory
9.How about the shipment?
We provide shipment by sea or by train according to your requirements.
10.How is your service?
We provide pre-sales,in-sales and after sales service within 24 hours