Certification: ISO9001, CE, ISO14001
Working Medium: R32
Heat Source Type: Air Source Heat Pump
Type: Air Source Heat Pump
Function: Heating, Cooling, Domestic Hot Water
ERP: a+++
Samples:
US$ 1500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Parameters
  • Heat Pump Project
  • Lab
Overview

Basic Info.

Model NO.
VDKS-12CB2B
Max Hot Water Temperature
60 Degree
Compressor
Famous Brand Twin Rotary Compressor
Air Side Heat Exchanger
Fin Copper Tube
Water Side Heat Exchanger
High Efficiency Tank
Refrigerant
R32
Sound Power Level
46dB
Warranty
2 Years
Motor Type
Brushless DC Motor
Water Pressure Drop
50kpa
WiFi
Available
Net Weight
98kg
Dimension
960*380*1270mm
Transport Package
Pallet+Plywood Case
Specification
960*380*1270mm
Trademark
Vegardis
Origin
Ganzhou, China
HS Code
8418612090
Production Capacity
3000PCS/Month

Product Description

12KW Air to water monobloc heat pump Power consumption lower than electric water heater
Product Feature

Energy class ERP A+++ 
High performance even at extreme temperatures
Outlet water up to 60°C for connection of radiators,
-35°C ultra low ambient temperature operation 

Complete Central Control with simple usage due to the touch control of your device
Easily remote control of the heat pump via WIFI 
Product Parameters
Model name VDKS-09CB2B VDKS-12CB2B VDKS-18CB2B
Power supply V / Ph  / H 220V / 50Hz
Heating 1
 A 7/6
ºC  W 30/35ºC
Capacity kW 9.20  12.10  18.70 
Rated input kW 1.99  2.50  4.02 
COP   4.61  4.84  4.67 
Heating 2
A 7/6
ºC  W 40/45ºC
Capacity kW 8.85  11.63  17.98 
Rated input kW 2.23  2.79  4.47 
COP   3.97  4.17  4.03 
Heating  3
A 7/6
ºC  W 50/55ºC
Capacity kW 8.00  10.52  16.26 
Rated input kW 2.62  3.28  5.26 
COP   3.05  3.21  3.09 
Heating  4
A -7/-8
ºC W 30/35ºC
Capacity kW 7.13  10.23  14.50 
Rated input kW 2.24  3.06  4.50 
COP   3.18  3.34  3.22 
Heating  5
A -7/-8
ºC W 50/55ºC
Capacity kW 6.20  8.16  12.61 
Rated input kW 2.95  3.69  5.91 
COP   2.11  2.21  2.13 
Heating  6
A -12/-14
ºC  W 36/41ºC
Capacity kW 6.22  8.18  12.64 
Rated input kW 2.43  3.04  4.87 
COP   2.56  2.69  2.59 
Heating  7
A -20/-
ºC  W -/41ºC
Capacity kW 5.48  7.20  11.13 
Rated input kW 2.51  3.14  5.03 
COP   2.18  2.29  2.21 
Cooling 8
A35/24
ºC  W 12/7ºC
Capacity kW 7.90  10.40  11.40 
Rated input kW 2.62  3.42  3.87 
EER   3.01  3.04  2.94 
Seasonal space heating
energy efficiency class 
LWT at 35ºC A+++ A+++ A+++
LWT at 55ºC A++ A++ A++
SCOP LWT at 35ºC 4.68  4.75  4.50 
LWT at 55ºC 4.06  4.12  3.90 
SEER LWT at 7ºC 4.65  4.72  4.47 
Water pressure drop kPa 55 50 50
Refrigerant Type R32 R32 R32
Charged kg 1.5 1.8 2.1
Compressor Type  DC inverter  DC inverter  DC inverter
Quantity 1 1 1
Capacity kW 8.65  16.66  16.66 
Input kW 2.26  4.30  4.30 
Fan motor Fan type Axial Fan Axial Fan Axial Fan
Motor type Brushless DC motor Brushless DC motor Brushless DC motor
Motor Quantity 1 2 2
Speed rpm 300~1000
  Electronic expansion valve
Water side heat-exchanger High efficiency tank
Sound power level6 dB 45 46 58
Water resistance IPX4 IPX4 IPX4
Net/Gross weight Net kg 68 98 108
Dimension (L×H×D) Net mm 960*380*820mm 960*380*1270mm 960*380*1270mm
Packing mm 1040*505*970mm 1040*505*1420mm 1040*505*1420mm
Loading quantity (20GP/40GP) sets 44/88 22/46 22/46
Operating temperature Cooling ºC - 5 to 43
Heating ºC - 30 to 35
DHW ºC -30 to 43
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.            
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 40ºC,LWT 45ºC.          
3.Outdoor air temperature 7ºC DB,6ºC WB;EWT 50ºC,LWT 55ºC.          
4.Outdoor air temperature -7ºC DB,-8ºC WB;EWT 30ºC,LWT 35ºC.          
5. Outdoor air temperature  -7ºC DB,-8ºC WB;EWT 50ºC,LWT 55ºC.          
6.Outdoor air temperature  -12ºC DB,-14ºC WB;EWT 36ºC,LWT 41ºC.          
7.Outdoor air temperature  -20ºC LWT 41ºC          
8.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.          
12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater
12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater
FAQ
1: How many years have your company been in heat pump industry?

over 15 years in heat pump industry,We used to focus on China domestic market,and we entered the international market since 2018. 

2: Do you accept OEM & ODM?
  Yes. We can produce high quality custom made air source heat pump according to customers' requirement, modify the products to satisfy client's requirements and work together with clients to design a new product.

3: What support do you offer to clients?
  We can provide product certification requirements for local markets; provide catalogs, technical manuals;

4: How long is your Heat Pump delivery time?
Generally production time will be 30 days,

5: What is your terms of payment for heat pump ?
For small order(USD10,000) 100% prepaid in advance. For big order 30% T/T in advance ,balance before shipment.

6: How long can I get feedback after sending inquiry
We will check inquiry and message everyday.Our sales clerk will reply to you accordingly in 24 hours. Please complete your email and telephone or mobile number in your personal information so that we can contact you soon.
 
7:How about the quality control?
   Finished products 100% inspected before package
 
8:How about the shipment?
   We provide shipment by sea or by train according to your requirements.
Heat Pump Project

12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater

Lab

 

12kw Air to Water Monobloc Heat Pump Power Consumption Lower Than Electric Water Heater  


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
50000000 RMB
Plant Area
30000 square meters