• Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water
  • Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water
  • Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water
  • Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water
  • Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water
  • Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water

Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water

Certification: ISO9001, CE, ISO14001
Working Medium: R32
Heat Source Type: Air Source Heat Pump
Color: Black
Warranty: 2 Years
APP-Control: Yes
Samples:
US$ 1700/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Diamond Member Since 2023

Suppliers with verified business licenses

Jiangxi, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (29)
  • Overview
  • Product Parameters
  • Product Description
  • FAQ
  • CE Certificate
  • ERP Label
Overview

Basic Info.

Model NO.
VLKS-06CPB2B
OEM
Yes
Installation
Freestanding
Lead Time
25-35 Days
Water Pump
Wilo
Certificates
CE,ERP a+++
Max Outlet Water Temp.(R290)
60ºC
Compressor
Famous Brand DC Inverter Twin Rotary
Type
Monobloc
Refrigerant
R32
Heat Exchanger
Plate Heat Exchanger
Noise Level
46dB
Air Side Heat Exchanger
Copper Tube and Hydrophilic Aluminum Fin
Transport Package
Plastic Bag Inside with Wooden Frame
Specification
1115mm*710mm*425mm
Trademark
OEM
Origin
China
HS Code
8418612090
Production Capacity
30000 Pieces/Year

Product Description

6kw Low temperature R32 air source heat pump for Fan Coil Unit Cooling radiator heating and hot water
ECO friendly new refrigerant: R32
GWP (Global Warming Potential) only 675, only approximately 1/3 compare with R410A.
Higher efficient technology:
15 years in manufacturing heat pump
Well-known brand Mitsubishi compressor, twin-rotary and DC Inverter technology, the twin rotors balance each other for anti-vibration,creates lower noise and more efficient.
Welling Brushless DC fan motor, with good quality of long time running test and low noise.
Saginomiya brand electronic expansion valve for precise refrigerant control.
Wilo DC inverter Water pump,Low noise, low vibration, high efficiency, high reliability, easy maintenance
Brushless DC motor
High COP/EER performance for save energy

Product Parameters

  
Model   VLKS-06CPB2B VLKS-09CPB2B VLKS-12CPB2B VLKS-16CPB2B
Heating capacity A7/W35ºC(EN14511) KW 6.21KW 8.9KW 12KW 16.3
Heating capacity A2/W35ºC(EN14511) KW 5.56 7.97 10.8 14.49
COP A2/W35(EN14511)     4.56 4.53 4.43 4.49
COP A7/W35 (EN14511)   4.93 4.92 4.8 4.88
Cooling capacity A35/W7ºC KW 4.9 5.9 8.1 11.4
EER A35/W7 (EN14511)   2.97 2.95 2.86 2.85
Cooling capacity A35/18 (EN14511) KW 6.35 8.1 11 15.6
EER A35/W18 (EN14511)   3.97 3.89 3.53 3.63
Electric supply   230V/50Hz 230V/50Hz 230V/50Hz 230V/1Ph Hz
Refrigerant   R32
Unit dimensions LXWXH mm 1115x425X710 1115x425x710 1115x425x960 1115x425x1280
Package dimension LXWXH mm 1160x520x860 1160x520x860 1160x520x1110 1160x520x1440
Net Weight Kg 90 90 105 140
Noise level dB(A) 46 46 50 52
Loading quantity for 20'/40'   44/88 44/88 44/88 22/44

Product Description

Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water

Monobloc Air Source Heat Pumps Working Principle Diagram
Vegardis provides the monobloc heat pump with an integrated main circulation pump. During installation, the installer needs to ensure the proper connection of the heat pump with other components, such as the buffer tank (for space heating/cooling), storage water tank (for domestic hot water), and water pumps (for circulating space heating/cooling water and domestic hot water)Additionally, external fittings are required, including the safety valve, water refill valve, and hot water valves (three-way valve). lt is necessary to incorporate a temperature sensor in the storage water tank. Furthermore, an additional electric heater can be installed in either the DHW tank or the buffer tank, allowing it to receive control signals from the heat pump.

Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot WaterLow Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water

 

FAQ

Q: How many years have your company been in heat pump industry?
A: over 15 years in heat pump industry with 200 staff and experienced engineer team,owns 50,000 sq meters workshop

Q: Do you accept OEM & ODM?
A: Yes. We can produce high quality custom made airsource heat pump according  to customers* requirement, modify the products to satisfy client's requirements and work together with clients to design a new product.

Q: What support do you offer to clients?
A: We can provide product certification requirements for local markets; provide catalogs, technical manuals.

Q: How long is your Heat Pump production time?
A: Generally production time will be 25-40 days.

Q: What is your terms of payment for heat pump ?
A: For small order<USD10,000, 100% paid in advance. 30% T/T in advance ,balance before shipment.

Q: How long can I get feedback after sending inquiry
A: We will check inquiry and message everyday.Our sales clerk will reply to you accordingly in 24 hours. Please complete your email and telephone or mobile number in your personal information so that we can contact you soon.

Q: How about the quality control?
A: Finished products 100% inspected before package.

Q: How about the shipment?
A: We provide shipment by sea or by train according to your requirements.

CE Certificate

Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water

ERP Label

Low Temperature 6kw R32 Air Source Heat Pump for Fan Coil Unit Cooling Radiator Heating and Hot Water

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
166
Year of Establishment
2010-11-11