• China Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, Cooling
  • China Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, Cooling
  • China Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, Cooling
  • China Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, Cooling
  • China Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, Cooling
  • China Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, Cooling

China Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, Cooling

Certification: ISO9001, CE, ISO14001
Working Medium: R32
Heat Source Type: Air Source Heat Pump
Model: Mls-Am-120
Type: Air Source Heat Pump
Function: Heating/Cooling/Dhw
Samples:
US$ 1900/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Parameters
Overview

Basic Info.

Model NO.
MLS-AM-120
Efficiency
a+++
Max Hot Water Temperature
60 Degree
Compressor
Mitsubishi
Water Pump
Wilo
Power Supply
230V/50-60Hz
Compressor Type
DC Inverter Twin Rotary Compressor
Heat Exchanger
Plate Heat Exchanger
Max Current
13A
Refrigerant
R32
Air Flow
2100m3/H
Warranty
2 Years
Noise Level
46dB
Transport Package
Pallet+Plywood+Carton Box
Specification
1115*425*910mm
Trademark
Vegardis
Origin
Ganzhou, China
HS Code
8418612090
Production Capacity
3000PCS/Month

Product Description

R32 Full DC Inverter Monoblock Heat Pump Hot Sale in Europe ERP A+++
Feature:
World famous brand compressor
Super Low Noise
Heating,cooling and domestic hot water 
Product Parameters
Model   MLS-AM-60 MLS-AM-90 MLS-AM-120 MLS-AM-160
Heating output/Power input/COP A20/W35ºC KW/KW/- 8.44/1.41/5.99 12.1/2.02/5.99 16.32/2.77/5.89 21.88/3.66/5.98
Heating output/Power input/COP A7/W35ºC KW/KW/- 6.21/1.26/4.93 8.9/1.81/4.92 12/2.5/4.8 16.3/3.34/4.88
Heating output/Power input/COP A7/W45ºC KW/KW/- 5.91/1.48/3.99 8.46/2.12/3.99 11.29/3.08/3.67 15.31/3.88/3.95
Heating output/Power input/COP A2/W35ºC KW/KW/- 5.56/1.22/4.56 7.97/1.76/4.53 10.8/2.44/4.43 14.49/3.23/4.49
Heating output/Power input/COP A2/W45ºC KW/KW/- 5.32/1.45/3.67 7.61/2.07/3.68 10.16/3.01/3.38 13.78/3.8/3.63
Cooling output/Power input/EER A35/W18ºC KW/KW/- 6.35/1.6/3.97 8.1/2.08/3.89 11/3.12/3.53 15.6/4.3/3.63
Cooling output/Power input/EER A35/W7ºC KW/KW/- 4.9/1.65/2.97 5.9/2/2.95 8.1/2.83/2.86 11.4/4/2.85
Compressor   Mitsubishi Mitsubishi Mitsubishi Mitsubishi
Max Current A 13 13 19 25
Electric supply   230V/50Hz 230V/50Hz 230V/50Hz 230V/1Ph Hz
Max LWT ºC 60
Operating temperature range ºC -25~43
Refrigerant   R32
DC Inverter compressor   Twin Rotary
Heat Exchanger   Copper and Hydrophilic Aluminum Fin
Air flow M³/h 2100 2400 2900 5600
Heat exchanger   Plate heat exchanger
In/Out pipe   DN25(1") DN25(1") DN25(1") DN32
Water flow M³/h 0.8 1.2 1.8 2.3
Permitted pressure   0.8MPa
Unit dimensions LXWXH mm 1115x425X710 1115x425x710 1115x425x960 1115x425x1280
Package dimension LXWXH mm 1160x520x860 1160x520x860 1160x520x1110 1160x520x1440
Net Weight Kg 90 90 105 140
Gross weight Kg 102 102 115 140
Noise level dB(A) 46 46 50 52
Loading quantity for 20'/40'   44/88 44/88 44/88 22/44

China Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, Cooling

Monobloc Air Source Heat Pumps Working Principle Diagram.
Vegardis provides the monobloc heat pump with an integrated main circulation pump. During installation, the installer needs to ensure the proper connection of the heat pump with other components, such as the buffer tank (for space heating/cooling), storage water tank (for domestic hot water), and water pumps (for circulating space heating/cooling water and domestic hot water)Additionally, external fittings are required, including the safety valve, water refill valve, and hot water valves (three-way valve). lt is necessary to incorporate a temperature sensor in the storage water tank. Furthermore, an additional electric heater can be installed in either the DHW tank or the buffer tank, allowing it to receive control signals from the heat pump.
China Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, CoolingChina Factory Vegardis R32 Air Source Heat Pump Space Underfloor Heating, Cooling


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
50000000 RMB
Plant Area
30000 square meters