Customization: | Available |
---|---|
Certification: | RoHS, ISO9001, CE, ISO14001,ISO45001 |
Working Medium: | R32 |
Still deciding? Get samples of US$ 1700/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
16kw R32 DC Inverter Air to Water Monoblock Heat Pump for Home Use
1.User-friendly touchscreen control panel
2.Built in WiFi, enables control and monitoring the heat pump from computer or smart device
3.Automatic restart in case of a power failure
4.Operates in conditions down to -25°C
5.Low investment -short payback time
6.Low noise outdoor unit
7.Eco-friendly refrigerant R32 enables A+++
8.Anti-freeze protection devic
Model | VLKS-06CPB2B | VLKS-09CPB2B | VLKS-12CPB2B | VLKS-16CPB2B | |
Heating capacity A7/W35ºC(EN14511) | KW | 6.21KW | 8.9KW | 12KW | 16.3 |
Heating capacity A2/W35ºC(EN14511) | KW | 5.56 | 7.97 | 10.8 | 14.49 |
COP A2/W35(EN14511) | 4.56 | 4.53 | 4.43 | 4.49 | |
COP A7/W35 (EN14511) | 4.93 | 4.92 | 4.8 | 4.88 | |
Cooling capacity A35/W7ºC | KW | 4.9 | 5.9 | 8.1 | 11.4 |
EER A35/W7 (EN14511) | 2.97 | 2.95 | 2.86 | 2.85 | |
Cooling capacity A35/18 (EN14511) | KW | 6.35 | 8.1 | 11 | 15.6 |
EER A35/W18 (EN14511) | 3.97 | 3.89 | 3.53 | 3.63 | |
Electric supply | 230V/50Hz | 230V/50Hz | 230V/50Hz | 230V/1Ph Hz | |
Refrigerant | R32 | ||||
Unit dimensions LXWXH | mm | 1115x425X710 | 1115x425x710 | 1115x425x960 | 1115x425x1280 |
Package dimension LXWXH | mm | 1160x520x860 | 1160x520x860 | 1160x520x1110 | 1160x520x1440 |
Net Weight | Kg | 90 | 90 | 105 | 140 |
Noise level | dB(A) | 46 | 46 | 50 | 52 |
Loading quantity for 20'/40' | 44/88 | 44/88 | 44/88 | 22/44 |
Variable Speed: Unlike fixed-speed compressors that operate at a constant speed, inverter compressors can adjust their speed based on the heating or cooling demand. This allows them to operate at lower speeds during periods of low demand, resulting in reduced noise levels.
Smoother Operation: Inverter compressors provide a smoother and more consistent operation, minimizing the vibrations and mechanical noises that can be generated by fixed-speed compressors.
Optimized Control: Inverter technology enables more precise control of the compressor's operation, allowing for adjustments that can help to reduce noise levels.
Working Principle of Monoblock Air Source Heat Pumps
A monoblock air source heat pump can be thought of as a "heat mover" that transfers heat from the outside air to the inside of a building, or vice versa.
Winter: The heat pump absorbs heat from the outside air, undergoes a series of processes, and then releases this heat into the building, making the indoor space warmer.
Summer: The heat pump absorbs heat from the inside of the building and releases it outdoors, making the indoor space cooler.
The whole process is mainly completed by a substance called refrigerant. The refrigerant continuously absorbs and releases heat during the compression, liquefaction, expansion, and gasification processes, thereby achieving heat transfer.
In summary, the Monoblock air source heat pump uses the heat of nature to achieve indoor temperature regulation through the circulation of refrigerant.