Customization: | Available |
---|---|
Energy Efficiency Grade: | One |
Heat Temperature: | 50-70°C |
Still deciding? Get samples of US$ 1580/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Since founded in 2004 Molisi Technology offers the best solution for heating cooling and hot water supply with dc inverter technology. Vegardis heat pump has been committed to saving energy and lower carbon emission.
Molisi Factory has obtained ISO9001, ISO14001,ISO45001 certificates
Main products:
R290/R32 gas air to water heat pump
EVI air to water heat pump
air source heat pump
Advantage:
15 years exporting experience
Strong R&D team
Custom made service
CE certificate,ERP A+++
As an international enterprise targeting the global market, Molisi attaches great importance to high-end global market, Till now our products have exported to over 30 countries and region.
Model name | VDKS-09CB2B | VDKS-12CB2B | VDKS-18CB2B | ||
Power supply | V / Ph / H | 220V / 50Hz | |||
Heating 1 A 7/6ºC W 30/35ºC |
Capacity | kW | 9.20 | 12.10 | 18.70 |
Rated input | kW | 1.99 | 2.50 | 4.02 | |
COP | 4.61 | 4.84 | 4.67 | ||
Heating 2 A 7/6ºC W 40/45ºC |
Capacity | kW | 8.85 | 11.63 | 17.98 |
Rated input | kW | 2.23 | 2.79 | 4.47 | |
COP | 3.97 | 4.17 | 4.03 | ||
Heating 3 A 7/6ºC W 50/55ºC |
Capacity | kW | 8.00 | 10.52 | 16.26 |
Rated input | kW | 2.62 | 3.28 | 5.26 | |
COP | 3.05 | 3.21 | 3.09 | ||
Heating 4 A -7/-8ºC W 30/35ºC |
Capacity | kW | 7.13 | 10.23 | 14.50 |
Rated input | kW | 2.24 | 3.06 | 4.50 | |
COP | 3.18 | 3.34 | 3.22 | ||
Heating 5 A -7/-8ºC W 50/55ºC |
Capacity | kW | 6.20 | 8.16 | 12.61 |
Rated input | kW | 2.95 | 3.69 | 5.91 | |
COP | 2.11 | 2.21 | 2.13 | ||
Heating 6 A -12/-14ºC W 36/41ºC |
Capacity | kW | 6.22 | 8.18 | 12.64 |
Rated input | kW | 2.43 | 3.04 | 4.87 | |
COP | 2.56 | 2.69 | 2.59 | ||
Heating 7 A -20/-ºC W -/41ºC |
Capacity | kW | 5.48 | 7.20 | 11.13 |
Rated input | kW | 2.51 | 3.14 | 5.03 | |
COP | 2.18 | 2.29 | 2.21 | ||
Cooling 8 A35/24ºC W 12/7ºC |
Capacity | kW | 7.90 | 10.40 | 11.40 |
Rated input | kW | 2.62 | 3.42 | 3.87 | |
EER | 3.01 | 3.04 | 2.94 | ||
Seasonal space heating energy efficiency class |
LWT at 35ºC | A+++ | A+++ | A+++ | |
LWT at 55ºC | A++ | A++ | A++ | ||
SCOP | LWT at 35ºC | 4.68 | 4.75 | 4.50 | |
LWT at 55ºC | 4.06 | 4.12 | 3.90 | ||
SEER | LWT at 7ºC | 4.65 | 4.72 | 4.47 | |
Water pressure drop | kPa | 55 | 50 | 50 | |
Refrigerant | Type | R32 | R32 | R32 | |
Charged | kg | 1.5 | 1.8 | 2.1 | |
Compressor | Type | DC inverter | DC inverter | DC inverter | |
Quantity | 1 | 1 | 1 | ||
Capacity | kW | 8.65 | 16.66 | 16.66 | |
Input | kW | 2.26 | 4.30 | 4.30 | |
Fan motor | Fan type | Axial Fan | Axial Fan | Axial Fan | |
Motor type | Brushless DC motor | Brushless DC motor | Brushless DC motor | ||
Motor Quantity | 1 | 2 | 2 | ||
Speed | rpm | 300~1000 | |||
Electronic expansion valve | |||||
Water side heat-exchanger | High efficiency tank | ||||
Sound power level6 | dB | 45 | 46 | 58 | |
Water resistance | IPX4 | IPX4 | IPX4 | ||
Net/Gross weight | Net | kg | 68 | 98 | 108 |
Dimension (L×H×D) | Net | mm | 960*380*820mm | 960*380*1270mm | 960*380*1270mm |
Packing | mm | 1040*505*970mm | 1040*505*1420mm | 1040*505*1420mm | |
Loading quantity (20GP/40GP) | sets | 44/88 | 22/46 | 22/46 | |
Operating temperature | Cooling | ºC | - 5 to 43 | ||
Heating | ºC | - 30 to 35 | |||
DHW | ºC | -30 to 43 | |||
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC. | |||||
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 40ºC,LWT 45ºC. | |||||
3.Outdoor air temperature 7ºC DB,6ºC WB;EWT 50ºC,LWT 55ºC. | |||||
4.Outdoor air temperature -7ºC DB,-8ºC WB;EWT 30ºC,LWT 35ºC. | |||||
5. Outdoor air temperature -7ºC DB,-8ºC WB;EWT 50ºC,LWT 55ºC. | |||||
6.Outdoor air temperature -12ºC DB,-14ºC WB;EWT 36ºC,LWT 41ºC. | |||||
7.Outdoor air temperature -20ºC LWT 41ºC | |||||
8.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC. |
1.How many years have your company been in heat pump industry?
Over 15 years in heat pump industry with 200 staff,20 engineers team
2.Do you have laboratory?
45KW Air Source Heat Pump Unit Performance Laboratory
applicable refrigerant: R290, R32,410A, R134A, R22, R404A, R407A,
laboratory air-side dry bulb temperature control range: -35 ~ +50 ºC;
3. Do you accept OEM & ODM?
Yes. We can produce high quality custom made air source heat pump according to customers' requirement, modify the products to satisfy client's requirements and work together with clients to design a new product.
4. What support do you offer to clients?
We can provide product certification requirements for local markets; provide catalogs, technical manuals;
5.How long is the Heat Pump delivery time?
Generally production time will be 25-40 days,
6.What is your terms of payment for heat pump ?
For small order,100% paid in advance. For big order 30% T/T in advance ,balance before shipment.
7.How long can I get feedback after sending inquiry
We will check inquiry and message everyday.Our sales clerk will reply to you accordingly in 24 hours. Please complete your email and telephone or mobile number in your personal information so that we can contact you soon.
8.How about the quality control?
Finished products 100% inspected before package,ISO9001 factory,first product will be test in laboratory
9.How about the shipment?
We provide shipment by sea or by train according to your requirements.
10.How is your service?
We provide pre-sales,in-sales and after sales service within 24 hours